INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing the Hard Disk Drive
Page 6-9Recovering from a Hard Disk Drive 0 Failure
6
Figure 6-5. Information Window
d. Press .
The system displays the Alarm Management window (Figure 6-4
).
Reconfiguring Both Hard Disk Drives
Because the Lucent INTUITY system must boot off of a hard disk drive with the
jumpers configured to be SCSI ID 0, you must reconfigure both hard disk drives.
To reconfigure both hard disk drives, do the following:
1. Remove Hard Disk Drive 0. See ‘‘Hard Disk Drive 0 Removal’’
below for the
procedure.
!
CAUTION:
Return to Step 2 of this procedure before you install the replacement
hard disk drive.
2. Remove Hard Disk Drive 1. See ‘‘Hard Disk Drive 1 Removal’’ below for the
procedure.
!
CAUTION:
Return to Step 3 of this procedure before you reinstall Hard Disk
Drive 1.
3. Change the jumpers for Hard Disk Drive 1 to the correct positions for Hard
Disk Drive 0. See ‘Setting the Hard Disk Drive 0 Jumper Settings’’
below
for the correct settings.
4. Replace the changed Hard Disk Drive 1 in the position reserved for Hard
Disk Drive 0. See ‘Inserting Hard Disk Drive 0’’
below for the procedure.
NOTE:
This hard disk drive is now Hard Disk Drive 0.
5. Set the jumpers on the new hard disk drive to the correct positions for
Hard Disk Drive 1. See ‘‘Setting the Hard Disk Drive 1 Jumper Settings’’
below for the correct settings.
ENTER