Basic drivers 19
4. If you have selected the RBS T1 switch type:
Select the trunk type that corresponds to the trunk type of your switch:
Wink Start
Loop Start
Ground Start
Default setting is Wink Start.
All trunk types are defined in the TIA/EIA-464B specification; the Wink Start trunk
type is also defined in AT&T TR4158.
Select the dial type that corresponds to the dial type of your switch.
Pulse
DTMF (Dual-Tone Multifrequency Signaling)
MF (Multifrequency Signaling)
Default setting is DTMF. Most analog telephones use dual-tone multifrequency
signaling.
5. If you have selected the Q-Sig switch type:
Select your PBX Type from the list. If your PBX is not listed, select Generic PBX.
Specify the Q-Sig standard. Normally, the correct Q-Sig standard is automatically
set for the selected PBX type. Change this value only if your PBX requires a different
value.
Specifics of all Diva Server 4BRI and Voice 4BRI adapters
With a Diva Server 4BRI or Voice 4BRI adapter, each of the four controllers (controller [1]
to controller [4]) can be enabled or disabled individually. To do so, check or clear the check
boxes for each of them.