EiconCard P92 Installation Guide 25
Table 10. Creepage Distances
The creepage distances apply when installed in a normal office environment. The
creepage distances shown in parentheses apply where the local environment within
the PC is subject to conductive pollution or dry non-conductive pollution which
could become conductive due to condensation.
These distances can be checked by measuring between the adjacent parts as shown
below. X shows the clearance distance which is the shortest distance in air between
two points. Y shows the creepage path (along surfaces) between the same two points.
Figure 13. Typical Installation
Power Consumption
Check that power supply will not be overloaded. Maximum power consumption of
the board is stated on page 22. The user should check that the total power drawn by
the host computer, the EiconCard P92, and any other peripherals, does not exceed
the capability of the host power supply unit.
Clearance
X mm
Creepage
Y mm
Voltage used or generated by other
parts of the host or expansion card
Vrms or Vdc
2.0 2.4 (3.8) up to 50
2.6 3.0 (4.8) up to 125
4.0 5.0 (8.0) up to 250
4.0 6.4 (10.0) up to 300
x
y
203086-1.FM5 Page 25 Friday, February 28, 1997 10:35 AM